6.1.10Core StandardSafety Standard
Facilities and equipmentIsolation Facilities and Airborne Infection Control
Negative pressure isolation rooms are maintained with continuous differential pressure monitoring and HEPA filtration for airborne infectious diseases.
Compliance Criteria
- 1Negative pressure isolation rooms with anteroom and minimum −2.5 Pa differential
- 2Continuous pressure monitor display with visual and audible breach alarms
- 3Air changes per hour (ACH ≥ 12) tested and certified semi-annually
- 4Appropriate N95 respirator fit-testing and PPE supply for isolation suites
Hospital Self-Rating
Rated by Dr. Tan Mei Ling on 18 Jan 2026Evidence frozen on 30 March 2026 (14 days before survey)
"Negative pressure isolation rooms in ICU and Emergency maintain differential pressure > −2.5 Pa with certified HEPA filtration logs."
thin
Evidence documents establish procedural intent but lack documented verification records for the current audit period.
Unverified criteria:
- Air changes per hour (ACH ≥ 12) tested and certified semi-annually
- Appropriate N95 respirator fit-testing and PPE supply for isolation suites
Derived from AccrediSense Evidence Engine · 1 document(s) attached with 2 unverified criteriaGovernance disclosure (1.4.1.4)
Evidence Documents (1)
CertificateAcceptedScore: 96/100
Negative Pressure Isolation Suite Differential Pressure Certification
12 pages · ENValid: 2025-11-01 to 2026-11-01
TL
Person-in-ChargeInfection Control Officer & Consultant Microbiologist
Head of DepartmentHead of Facilities & Biomedical Engineering
HO
Surveyor Authority PaneAssigned: Dr. Mohd Anis Haron (Lead Surveyor)